ATC1500-S適用于電源廠生產(chǎn)線測試使用. |
測試速度快,同時(shí)可迅速形成測試報(bào)表, |
有效的提高了工廠的品質(zhì)控制能力。 |
|
ATC1500-S
LED驅(qū)動(dòng)電源自動(dòng)系統(tǒng)
介 紹
適用:150W以下單路輸出之充電器,電源適配器,LED驅(qū)動(dòng)電源!
(客戶自備電腦+顯示器)
概述:
系統(tǒng)結(jié)構(gòu):測試架+ATC150主機(jī)(內(nèi)含 150W電子負(fù)載,功率計(jì)模塊,示波器模塊,AC源)
尺寸:500x450x133mm 總體重量:20KG
主要功能特點(diǎn):
1.可以測試150W以內(nèi)任何單組輸出電源
2.圖形界面基于Windows XP環(huán)境
3.測試程序編輯功能
4.測試項(xiàng)目選擇功能(輸入/輸出/空載/短路
5.欠壓/穩(wěn)壓/過載/紋波/效率等功能)
6.統(tǒng)計(jì)測試報(bào)告(Excel電子檔)
7.自動(dòng)生成CPK等品質(zhì)報(bào)表
8.配置靈活
9.性價(jià)比高,適合大中小企業(yè)。
10.測試速度快
11.測試不良結(jié)果實(shí)時(shí)打印功能
測試項(xiàng)目:
啟動(dòng)測試(Start-up)
欠壓測試(UVLO)
待機(jī)測試(Idle)
恒壓區(qū)測試(Standard CV)
恒流區(qū)測試(Standard CC)
LED驅(qū)動(dòng)電源測試(LED)
短路測試(Short Circuit)
過壓測試(Over Voltage)
過流測試(Over Current)
線調(diào)整(Line Regulation)
負(fù)載調(diào)整(Load Regulation)
關(guān)機(jī)測試(Power Down)
支持性測試(Support Function)
Test Name |
Parameter and Range(測試項(xiàng)目與量程) |
Accuracy |
START UP 啟動(dòng)測試 |
Inrush current: 0 – 83Apk Startup time: 0 to 32767msec. Output voltage overshoot: 0 – 60Vpk |
±1% (reading + range) ±1ms ±1% (reading + range) |
UVLO欠壓測試 |
Functional test only, Pass/Fail |
N/A |
IDLE待機(jī)測試 |
Standby input power: 0 – 5/25/250/1250W Standby input current: 0 – 0.1/0.5/5/25Apk Input voltage: 30 – 280V*Note 2 |
±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) |
STANDARD CV (Constant Current and Constant Resistance load) 恒流 |
CC Mode: 0 – 3/15 A CR Mode: 0.1 – 50Ohm Input Voltage: 30 – 300Vrms *Note 1 Input Current: 0 – 0.1/0.5/5/25Apk Input Power: 0 – 5/25/250/1250W Power Factor 0 – 1.0 Output Voltage 0 – 15/60Vdc Output Current 0 – 3/15Adc Efficiency: 0 – 100% Ripple/Noise 200kHz: 0 – 500mV Ripple/Noise 20MHz: 0 – 500mV |
±0.15% (setting + range) ±0.3% (setting + range) *Note 2 ±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.2% (reading + range) ±0.05% (reading + range) ±0.1% (reading + range) ±0.25% (reading + range) ±2% (reading + 5mV) ±2% (reading + 5mV) |
STANDARD CC (Constant Voltage and Constant Resistance load)恒壓 |
CV Mode: 0 – 15/60V CR Mode: 0.1 – 50Ohm Input voltage: 30 – 300Vrms *Note 1 Input Current: 0 – 0.1/0.5/5/25Apk Input Power: 0 – 5/25/250/1250W Power Factor 0 – 1.0 Output Voltage 0 – 15/60Vdc Output Current 0 – 15Adc Efficiency: 0 – 100% |
±0.15% (setting + range) ±0.3% (setting + range) *Note 3 ±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.2% (reading + range) ±0.05% (reading + range) ±0.1% (reading + range) ±0.25% (reading + range) |
LED Driver Test (LED Load) LED驅(qū)動(dòng) |
Input voltage: 30 – 300 Vrms *Note 1 Input Current: 0 – 5/25Apk Input Power: 0 – 250/1250W Power Factor 0 – 1.0 Output Average Current reading: 0 – 15Adc Output Average Voltage reading: 0 – 60Vdc Output pulsed current reading (TRIAC, PWM) |
±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.2% (reading + range) ±0.1% (reading + range) *Note 4 ±0.05% (reading + range) *Note 4 ±0.5% (reading + range) |
SHORT CIRCUIT
短路測試 |
Input voltage: 30 – 300 Vrms *Note 1 Input Current: 0 – 5/25Apk Input Power: 0 – 250/1250W Power Factor 0 – 1.0 Output Average Current: 0 – 15Adc |
±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.2% (reading + range) ±0.2% (reading + range) *Note 4 |
OVER CURRENT 過流 |
Current trip point: 0 – 3/15Adc Trip point voltage: 0 – 15/60Vdc Wait Time >= 10msec. Wait Time < 10msec. Voltage Before Trip Point: 0 – 15/60Vdc Current Before Trip Point: 0 – 3/15Adc |
±0.1% (reading + range)
±0.05% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) |
OVER VOLTAGE 過壓測試 |
OV trip point: 0 – 60V |
±0.1% (reading + range) |
LINE REGULATION 線性調(diào)整率 |
Voltage regulation: 0 – 100% |
±0.1% (reading + range) |
LOAD REGULATION 負(fù)載負(fù)整率 |
Voltage regulation: 0 – 100% |
±0.1% (reading + range) |
AVERAGE EFFICIENCY 平均效率 |
Efficiency: 0 – 100% |
±0.25% (reading + range) |
I-V CURVE PLOT I-V曲線 |
CC Mode: 0 – 3/15 A CC Mode Output Voltage 0 – 15/60Vdc CC Mode Output Current 0 – 3/15Adc CV Mode: 0 – 15/60V CV Mode Output Voltage 0 – 15/60Vdc CV Mode Output Current 0 – 15Adc |
±0.15% (setting + range) ±0.05% (reading + range) ±0.1% (reading + range) ±0.15% (setting + range) ±0.05% (reading + range) ±0.1% (reading + range) |
POWER DOWN 關(guān)機(jī)測試 |
Holdup time: 0 – 65535 msec. Input voltage: 30 – 300Vrms *Note 1 Output Current 0 – 3/15Adc Output voltage overshoot: 0 – 60Vpk |
±1ms ±0.1% (reading + range) ±0.1% (reading + range) ±1% (reading + range) |
Global Setting |
Load On Voltage: 0 – 60Vdc Wait Time: 0 – 32767msec. Nominal Output Voltage: 0 – 60Vdc Nominal Output Current: 0 – 15Adc |
±1% (reading + range) ±1ms ±1% (reading + range) ±1% (reading + range) |
Optional Setting 支持性功能 |
Bias Output Voltage : 0 – 28Vdc Relay State rated current: 3A |
±0.2% (reading + range) - |
STS帶給企業(yè)的優(yōu)勢
1.能有效地解決電源產(chǎn)品的功能測試,有效的排除了手工測試產(chǎn)生錯(cuò)誤的可能性!
2.能將測試數(shù)據(jù)完整地形成電子表格,永久存檔以便追溯。
3.有效地降低測試成本,為客戶贏取更多訂單!